  • Concrete Freeze-Thaw Cycle Test Chamber
  • Concrete Freeze-Thaw Cycle Test Chamber
  • Concrete Freeze-Thaw Cycle Test Chamber
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
TPDR-10/TPDR-16/TPDR-28
Capacity
10PCS;16PCS;28PCS
Specimen Size
100×100×400mm.
Transport Package
Wooden
Trademark
C-Tech
Origin
China
HS Code
90248000
Production Capacity
100PCS/Month

Product Description

Product Description

Concrete freeze-thaw cycle test chamber

It is used to determine the resistance of concrete specimens to repeated cycles of freezing and thawing in the laboratory by rapid freezing and thawing in water method.
 

STANDARD

  • ASTM C666
FEATURES
The compressor, heating device and power control part are all imported parts with high quality and high performance.
When running at full load, the temperature difference at each point in the freeze-thaw cabinet does not exceed ±2ºC.
Display data curves in real time and automatically store test data.
It has an automatic recovery function when the test is accidentally interrupted.
Easy installation, small footprint, low noise
 

TECHNICAL PARAMETERS

TPDR-10
Condenser cooling system: Air cooling
Specimen size: 100×100×400mm. The size of the specimen for temperature measurement is the same, a temperature measuring hole is required in the middle
Capacity: 10 pcs
Freeze-thaw cycle: 2.5~4 hours, the thawing time is not less than 1/4 freeze-thaw cycle
Center temperature control: 8~-17±2ºC
Liquid temperature control: High temperature: 18~23ºC; Low temperature: -23~-18ºC
Diagonal temperature control: The temperature difference in the cabinet does not exceed 1°C
Secondary protection temperature control: 50ºC~-30ºC
Temperature recorder: Touch screen
Freeze-thaw cycle medium: -45ºC antifreeze
Freeze-thaw cycle medium filling volume: The liquid level is 10-15mm higher than the specimen
Refrigerator compressor: Fully enclosed 3HP
Heating power: 3kW
Power supply: 3N380V 50Hz
Dimensions: 1750×800×1100mm

TPDR-16
Condenser cooling system: Air cooling
Specimen size: 100×100×400mm. The size of the specimen for temperature measurement is the same, a temperature measuring hole is required in the middle
Capacity: 16 pcs
Freeze-thaw cycle: 2.5~4 hours, the thawing time is not less than 1/4 freeze-thaw cycle
Center temperature control: 5~-18±2ºC
Liquid temperature control: High temperature: 18~23ºC; Low temperature: -23~-18ºC
Diagonal temperature control: The temperature difference in the cabinet does not exceed 2°C
Secondary protection temperature control: 50ºC~-30ºC
Temperature recorder: Touch screen
Freeze-thaw cycle medium: -45ºC antifreeze
Freeze-thaw cycle medium filling volume: The liquid level is 10-15mm higher than the specimen
Refrigerator compressor: Fully enclosed 5HP
Heating power: 4.5kW
Power supply: 3N380V 50Hz
Dimensions: 1760×900×1100mm

TPDR-28
Condenser cooling system: Air cooling
Specimen size: 100×100×400mm. The size of the specimen for temperature measurement is the same, a temperature measuring hole is required in the middle
Capacity: 28 pcs
Freeze-thaw cycle: 2.5~4 hours, the thawing time is not less than 1/4 freeze-thaw cycle
Center temperature control: 5~-18±2ºC
Liquid temperature control: High temperature: 18~23ºC; Low temperature: -23~-18ºC
Diagonal temperature control: The temperature difference in the cabinet does not exceed 2°C
Secondary protection temperature control: 50ºC~-30ºC
Temperature recorder: Touch screen
Freeze-thaw cycle medium: -45ºC antifreeze
Freeze-thaw cycle medium filling volume: The liquid level is 10-15mm higher than the specimen
Refrigerator compressor: Fully enclosed 6HP
Heating power: 6kW
 

Concrete Freeze-Thaw Cycle Test Chamber
Concrete Freeze-Thaw Cycle Test Chamber
Concrete Freeze-Thaw Cycle Test Chamber



Power supply: 3N380V 50Hz
Dimensions: Chamber 1450*1100*1700mm; Air cooling system 1950*900*1250mm