Rebar Location and Corrosion Measuring System

Product Details
Customization: Available
After-sales Service: All Life
Warranty: One Year
Still deciding? Get samples of US$ 1850/Piece
Request Sample
Manufacturer/Factory, Group Corporation

360° Virtual Tour

Diamond Member Since 2007

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
5000000 RMB
Plant Area
501~1000 square meters
  • Rebar Location and Corrosion Measuring System
Find Similar Products

Basic Info.

Model NO.
GW-50B
Tested Range of Concrete Cover Thickness
6-90mm, 7-180mm
Permissible Error of Steel-Bar Diameter
+-1 Grade
Power Supply
6 Dry Cells,Work More Than 30 Hours
Transport Package
Carton Box
Specification
10kg
Trademark
C-tech
Origin
China
HS Code
90248000
Production Capacity
500sets/Month

Product Description

REBAR LOCATION AND CORROSION MEASURING SYSTEM

Applications: Testing concrete cover thickness; Test concrete member internal reinforcement position, rebar spacing, reinforcement position distribution; Rebar corrosion.
 
Model GX-50B
Applicable steel-bar diameter dia.6mm~dia.50mm
Tested range of concrete cover thickness Low range:6mm~90mm;
High range:7mm~180mm
Tested range of Steel-bar diameter
dia.6mm~dia.50mm
 
Permissible error of Steel-bar diameter ±1 grade
Working environment Temperature:-10°C~+40°C Dampness:<90%RH EMI: no Strong electromagnetic field
Power supply 6 dry cells,work more than 30 hours

Corrosion specification
1.  Automatically monitor the ambient temperature without the help of thermometer.
2. Permanently fixed cupric sulfate-copper electrode. No need to perfuse and change cupric sulfate saturated solution both before and after the test, in order to avoid damage to the environment and testers.
3. Two measurement methods: potential method and gradient method, with potential electrode and gradient electrode respectively.
4. Measuring Potential:  ±2000mV;
5. Test accuracy: ± 1mV;
6. Measuring Space: 1-99 cm (adjustable)
7. Environment Requirement: Ambient Temperature:-10°C~+40°C, to avoid direct exposure to the sun for a long time. Relative Humidity:<90%RH; Electromagnetic Interference: no strong alternating electromagnetic field.

Rebar Location and Corrosion Measuring System

ABOUT TIANPENG

Zhuozhou Tianpeng (generally refers to Zhuozhou Tianpeng Imp. and Exp. Trade Co., Ltd & Zhuozhou Tianpeng Instrument Manufacturing Co., Ltd.) was founded in 2006, and specialize in the design, manufacture and supply of high-quality construction materials testing machine for concrete, soil, cement, asphalt and etc. We have more than 300 customers worldwide, including many of the major companies around the world. More than 10 years of industry experience, professional technical and service teams help us better meet customer needs, making us an ideal partner.


Rebar Location and Corrosion Measuring System

Rebar Location and Corrosion Measuring System
Rebar Location and Corrosion Measuring System
Rebar Location and Corrosion Measuring System
Rebar Location and Corrosion Measuring System
Rebar Location and Corrosion Measuring System
Rebar Location and Corrosion Measuring System
Rebar Location and Corrosion Measuring System
Rebar Location and Corrosion Measuring System

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier